On scantron import, cannot change points of an assignment unless either hitting return or clicking off the field
Description
Activity

James Renfro September 20, 2009 at 9:29 PM
Closing since this is a QA pass.

Vernon O'Connor September 17, 2009 at 1:49 PM
QA ENVIRONMENT:
Using PC Windows Vista Enterprise SP2 Firefox 3.5.3 & IE 8 on:
UCD TEST SERVER
SmartSite@UCDavis - [sakai_2-5-x-test-079] - Sakai 2.5.x-R57934 gb2-1.1.1-b1 - Server sakaitest2
with gradebook2 (tags/gb2-1.1.1-b1).
QA TASK:
Verify that one can now change points of an Item without having to either hit return or click off the field on scantron import.
QA SUMMARY:
ART 009 001 FQ 2009
QAQC GBNG 004 SUQ 2009
Scantron imports now allow points to be manually changed without having to either hit return or click off the field.
Verified that one can now change points of an Item without having to either hit return or click off the field on scantron import, QA Pass.
QA RESULTS:
Verified that one can now change points of an Item without having to either hit return or click off the field on scantron import, QA PASS.
Overall, QA PASS.

Nancy Wilkison September 17, 2009 at 10:20 AM
QA ENVIRONMENT -
vista enterprise, firefox, ie7
smartsite-test sakai_2-5-x-test-079 - Sakai 2.5.x-R57934 gb2-1.1.1-b1 - Server sakaitest1
QA SUMMARY -
followed test plan above.
1 - imported sample scantron w/500 points max scores
2 - popup gives warning that points value needs to be changed (grbk-363) - ok
3 - in import-setup, changed points and next (did not assign to cat so as not click anywhere
else on screen)
4 - came in Unassigned w/points intact - ok
5 - deleted and repeated to assign to cat in import-setup (grbk-364).
6 - set max points to 400 to assure scores of >400 don't come in. they don't but you don't
get another error so you CAN lose grades if you don't assign the max points high enough
in import-setup.
I guess you can only protect people from their own stupidity so much
QA RESULTS -
pass on -test

James Renfro September 16, 2009 at 2:15 PM
Executed M:1.1.x-dev and M:1.1.x-test by virtue of having executed them on GRBK-364.
Michael Wenk September 16, 2009 at 12:14 PM
M:1.1.x-dev
M:1.1.x-test
When importing a scantron file with points in the scantron greater than 100, you need to change the points of the assignment. However, changing the points of the assignment in the import workflow doesn't get accepted unless you either hit the return/enter key, or you click off the field.
Test plan:
1) Import a scantron
2) Click on Points for the assignment.
3) Enter a number of points, but do not hit enter or click anywhere else
4) Click next
5) Click done
It passes if the number entered for #3 is accepted for the points of the assignment
Workaround:
When entering points, press return/enter or click off the field.